Onsite supervisor must be qualified as the competent person in accor dance with wac 296155775. Wac 296155003 subsections, subdivisions, items, subitems, and segments. Major public project construction noise variance questions. Boom stop a device used to limit the angle of the boom at the highest recommended position. Lewis county public health social services environmental. Facility contract safety plans development guide policy. Inland northwest agc safety committee meeting november 03, 2016 page 1 of 1 agenda 1. When running water is not available, portable washing stations, with soap, are required, per wac 296155140 2a f. If chemicals being used are considered toxic, caustic, corrosive, flammable solvents, carcinogenic, mutagenic, or teratogenic, a minimum of disposable nitrile gloves is required. Wac 29615553400 43 applies, except for wac 29615553400 43 c iii qualified rigger. You must ensure that the cranederrick is inspected in accordance with manufacturer procedures.
Wac 296155336 through 29615534025 part g toolshand and power. This condition will apply to activity conducted between 10. Flagger means a person who provides temporary traffic control. Clark county public works traffic control permit the. Phase 1 construction restart covid19 job site requirements. Large pdf files should be printed a few pages at a time. You must ensure that equipment covered by this section is not used to hoist personnel. Boom point the outer extremity of the crane boom, containing the hoist sheave assembly. Guidelines for test pit construction for onsite sewage.
This permit is valid for the following dates and times to. The significant state standard amendment, which incorporated a washington industrial safety and health administration wisha regional directive wrd, references the 1980 society of automotive engineers sae test. Fall protection plan washington state department of. Pcb caulking work plan university of washingtons seattle. Wac 296155305 9 a when flaggers are used on a job that will last more than one day, the employer, responsible contractor andor project owner must keep onsite, a current site specific traffic control plan. The department alleged that there were nine previous violations of the same or similar standard with final orders within three years of the current violations. Part f1 rigging requirements for material handling.
Alcoholbased hand sanitizers with greater than 60% ethanol or 70% isopropanol can also be used, but are not a replacement for the water requirement. The purpose of this plan is to help move traffic through or around the construction zone in a way that protects the safety of the. For the purposes of this chapter, mutcd means the federal highway administrations manual on uniform traffic control as currently modified and adopted by the washington state department of transportation. The title of chapter 296876 wac will change to include fixed ladders. The pdf files below contain publication copies of the wac titles and chapters as published in 2012. Policy applicability department wide offender manual revision date 20 page number page of 4 number doc 890. Chapter 296155 wac part l construction work cranes. Personnel platform lift planning and authorization form. Use the least stable soil for evaluating test pit stability when there is a layered soil profile. Operator certificationwritten examinationtechnical knowledge criteria. The kinds of forklifts and powered industrial trucks commonly available.
Chapter 296155 wac construction work washington state. Also, we are incorporating requirements from the amer ican national standards institute ansi into this chapter, ansi a14. Pcb caulking work plan march 14, 2014 university of washingtons seattle campus uw project no. Guidelines for test pit construction for onsite sewage systems. On this page you can read or download autentico 1 workbook pdf answers guided practice 155 in pdf format.
Chapter 296155 wac safety standards for construction work. Boom point sheave assembly an assembly of sheaves and pin built as an integral part of the boom point. Within this washington administrative code wac, the applicable work area for where these standards apply is defined as. By definition, wac 296155 establishes safety standards for construction work. Chapter 296155 wac construction work part nexcavation, trenching, and shoring page 296155650 scope, application, and definitions applicable to this part. For dump trucks, if the surrounding noise level is so loud that broadband or strobe backup warning devices are not effective, then an observer must be used wac 296155610. The preferred implementation of the program is the use of ground fault circuit. As defined in wac 296 1550124, a competent person is capable of identifying existing and predictable hazards in the surroundings or working conditions which are dangero us and has the authorization to take prompt, corrective action. See wac 296155246097b whenever there is a danger of falling through an unprotected skylight opening, or the skylight has been installed and is not capable of sustaining the weight of a 200 pound person with a safety factor of 4, employers must provide standard guardrails on all exposed sides in accordance with wac 296155.
The pdf files below contain publication copies of the wac titles and chapters as published in 2019. Operations which involve construction work, as defined in chapter 296155 wac are subject to all the applicable standards contained in chapter 296155 wac, safety standards for construction work. Under wac 29680035040, which allows for an increase in the penalty for repeat. Avoid chemical transfer by taking off gloves when using anything other than the chemicals. Wac 296863 construction standard wac 2961556153 agriculture standard wac 296307520 longshore, stevedore and related. General industry regulations will apply to the majority of maintenance and service work performed by uw employees. One person will perform the work while one competent person, as defined in wac 29615524603. Should lead be detected at any concentration, wac 296155176 provides the appropriate methods of compliance to ensure worker safety from potential lead exposure. University of washington seattle, washington march 14, 2014. For information on determining roof widths, see wac 29615524623, appendix a, determining roof widths. Regardless of soil type, a test pit that shows distress such as fissures or cracks is deemed unstable.
Wac 29680031010 make sure that exit routes are large enough. Equipment service or repair work conducted on low pitched roofs no greater than 4. All employees working where there is a fall hazard of 10 feet or more. Washington state register, issue 0609 wsr 0609072 wsr. The principles that allow a forklift to lift and move heavy loads safely.
Autentico 1 workbook pdf answers guided practice 155. This is an archived version of the 2012 washington administrative code. This is an archived version of the 2019 washington administrative code for the current html version of the wac, go to the full wac page. Employees exposed to noise over an 8hr timeweighted. Qualifications for operators of belowthehook lifting devices. Chapter 296155 wac part e construction work signaling and.
Wac 296155950, rollover protective structures for material handling equipment. Clark county commdevpublic works event traffic control. For the purposes of wac 296155176, the requirement that an employer provide medical removal protection benefits means that, as long as the job the employee was removed from continues, you must maintain the total normal earnings, seniority and other employment rights and benefits of an employee. Appendix to wac 296 155 684 cast in place concrete. Guardrails which comply with chapter 296155 wac, part c1 shall be provided where walkways are 4 feet or more above lower levels. Outofservice the condition of a crane when unloaded, without power and with the controls unattended and prepared to endure winds above the inservice level.